circulator pump |
Posted: January 23, 2021 |
circulator pump The circulator pump is used to circulate the fluid in a reciprocating circuit, usually under closed pressure. The circulator pump is usually installed linearly on the pipe without changing the angle of suction and flow in one direction. Of course, it is not correct to consider all circular pump models as linear inline, because the ground circulator pump is also used in larger projects that do not respond to the flow and pressure of linear pumps. Circulator pump is any type of pump that is installed to circulate fluid in an open or closed round trip. This pump can be horizontal line, vertical line or ground line. What is a circulator pump? The circulator pump ??? ?????????? ???? usually has a launch height or low head. The circulator pump is selected according to the required flow in the heating, cooling, industrial and ? systems. Due to the need for continuous operation, the motor speed of the circulator pump is usually selected as 1450 rpm, which has less depreciation. Circulator pumps are produced in single, triple or variable speed. Some pumps are produced as cold water and some as air-cooled. In the cold water model of the electromotor, the pump is surrounded and cooled by circulating water. In the air-cooled model, as in conventional electric motors, cooling is done by the impeller of the pump pump sheet. Select the circulator pump To select a circulator pump, the required flow must be calculated according to the needs of the heating, cooling system, industrial systems, and so on. Path pressure drop, connection pressure drop, heat exchangers and… are calculated to obtain the pump head. 1450 rpm pumps are used to increase service life, lower noise and vibration. Use low-noise pumps whenever possible. Compact water-cooled pumps produced by Grandfoss and Dob brands and recently several Iranian brands are low-noise pumps, but the capacity of these pumps is low. The operating temperature of the fluid passing through the circuit must be in accordance with the operating temperature of the pump. The material of the body, impeller and pump shaft must conform to the pH of the fluid. When choosing a circulator pump, consider the operating point of the pump and do not use the maximum head and flow numbers as the selection criteria. In selecting the three circuits of the circulator, the head and discharge mentioned are related to the maximum speed, so be careful in choosing these pumps. The type of connection to piping in linear pumps is in the form of threaded connection with special pipe and flange connection. Flange connection is usually used in sizes higher than ½ 1 inch. The linear circulator pump is produced as single-phase or three-phase. If a three-phase circulating pump is available at the project site, it is better to use a three-phase circulating pump . Application Circulator Pumps Buy Circulator Pumps Direct and Save! Circulator pumps are designed to move a fluid within a closed circuit. In home or building water systems, circulator pumps are typically used to ensure that warm water remains moving through the piping so that it will be immediately available at the tap (as opposed to waiting for cold water to heat up). Circulator pumps can provide a way to save on energy costs. carries a variety of circulator pump types, such as in-line, single stage and solar circulators from a variety of top manufacturers like Armstrong, Grundfos and Taco. Accessory controls are also available.
|
||||||||||||||||
|